      Simulation study of integrated‐gate‐commutated‐thyristor based superconducting hybrid direct current circuit breaker

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          With the development of a distributed generation, direct current (DC) load and energy‐storage equipment, voltage‐source‐converter‐based medium‐voltage DC systems (VSC‐MVDC) have attracted more attention due to its low power consumption, high reliability, independent power control and so on. However, VSC‐MVDC has the problem of DC fault isolation, which requires the fast‐acting DC circuit‐breakers to isolate faulty lines and ensure low cost. This problem can be solved by coordinating resistive type superconducting‐fault‐current‐limiter (R‐SFCL) and integrated‐gate‐commutated‐thyristor (IGCT) based hybrid circuit breaker. Based on this, IGCT based superconducting DC circuit breaker (SDCCB) is proposed and analysed. Combining R‐SFCL with IGCT could realise large current limiting and interruption and ensure low cost. In addition, the IGCT based hybrid DC circuit breaker (IGCT‐HDCCB) is compared with the traditional insulated gate bipolar transistor (IGBT) based hybrid DC circuit breaker (IGBT‐HDCCB) to evaluate which circuit breaker is more suitable for VSC‐MVDC. The results show that, coordination based on R‐SFCL and SDCCB, the fault current is successfully limited from 17.6 to 2.1 kA, and then interrupted within 3.8 ms. In addition, IGCT‐HDCCB overcomes the disadvantage that IGCT has less interrupting capacity than IGBT, retains the advantage of low cost of IGCT and is more suitable for MVDC system.

          Related collections

          Most cited references31

          • Record: found
          • Abstract: not found
          • Article: not found

          Technical Assessment of Load Commutation Switch in Hybrid HVDC Breaker

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Multiterminal HVDC Networks—What is the Preferred Topology?

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Research on Current Commutation Measures for Hybrid DC Circuit Breakers

                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                Journal
                High Voltage
                High Voltage
                Institution of Engineering and Technology (IET)
                2397-7264
                2397-7264
                December 2023
                May 23 2023
                December 2023
                : 8
                : 6
                : 1275-1284
                Affiliations
                [1 ] School of Electrical Engineering China University of Mining and Technology Xuzhou China
                [2 ] State Key Laboratory of Electrical Insulation and Power Equipment Xi'an Jiaotong University Xi'an China
                Article
                10.1049/hve2.12332
                615eb557-e1c5-400c-a12f-c9f6e8af617d
                © 2023

                http://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article