      Toward the definition of a new worst-case paradigm for the preclinical evaluation of posterior spine stabilization devices.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Mechanical reliability tests on posterior spine stabilization devices are based on standard F1717 by the American Society for Testing and Materials, which describes how to assemble the implant with vertebrae-like test blocks in a corpectomy model. A recent study proposed to revise the standard to describe the anatomical worst-case scenario, instead of the average one currently implemented, and introduce the unsupported screw length as a mechanical parameter. This article investigates the implications of such revisions on the endurance properties of an implant already on the market. Experimental fatigue tests demonstrate that the revision of F1717 standard leads to a reduction of 3.2 million cycles in the fatigue strength of the tested implant: this amount is comparable to the run-out number of cycles (5 million cycles) currently recommended. The numerical analysis, validated with static tests and strain gauges, supports the experimental findings and demonstrates that the stress on the implant may increase upon revision up to a 50% on the screw (most recurrent failure mode), with the unsupported screw length contributing alone up to 40%. The revision of ASTM F1717 standard would guarantee higher safety for the implant to test, potentially covering for a wider population of patients.

          Related collections

          Author and article information

          Journal
          Proc Inst Mech Eng H
          Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
          SAGE Publications
          2041-3033
          0954-4119
          Feb 2017
          : 231
          : 2
          Affiliations
          [1 ] 1 Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta," Politecnico di Milano, Milan, Italy.
          [2 ] 2 IRCCS Galeazzi Orthopedic Institute, Milan, Italy.
          Article
          10.1177/0954411916684365
          28095745
          f5c262b7-d781-4cc1-9fc5-028c330946dd
          History

          ASTM F1717,ISO 12189,experimental tests,fatigue,finite element,pedicle screw,preclinical evaluation,spine stabilization,standard,strain gauges,unsupported screw length

          Comments

          Comment on this article